Cambio - Excellence in Molecular Biology

PCR

PCR : Extra-long PCR

MasterAmp Extra-Long PCR kit, amplifies up to 40kb

MasterAmp™ PCR Optimisation Kits- Discontinued Please See FailSafe PCR Optimisation System

MasterAmp™ PCR Optimisation Kits Three Steps to Successful Extra-Long PCR

BioSearch Tech (Lucigen/Epicentre)

Catalogue No.DescriptionPack SizePriceQty
MO7201-Discontinued See Failsafe PCR Optimisation SystemMasterAmp™ PCR Optimisation Kit (without Ammonium Sulphate)60 Templates POA Quantity Add to Order

Description

Please note: This product is no longer available.

Please see the Failsafe PCR optimisation system as an equivalent alternative

 

Optimize PCR reactions that use different enzymes than the FailSafe™ System (e.g. Taq, Pfu, and Tth).

  • Fast, simple optimization
  • Extremely high sensitivity and specificity using the PCR Enhancer Technology
  • MasterAmp PCR PreMixes contain all components needed for successful PCR
  • Generates PCR products suitable for both TA cloning and blunt-end cloning
  • Use for the optimization of PCR reactions using a variety of different enzymes including Taq, Pfu, Tth, Tfl polymerases



Applications
  • Simplified PCR optimization with a thermostable DNA polymerase of choice.
  • PCR of difficult or high-GC templates.
  • PCR amplifications up to 20 kb.
  • Multiplex PCR.

For rapid, dependable optimization of PCR, we encourage you to try the FailSafe™ PCR System to obtain the best PCR results with any template up to ~20 kb. However, if you prefer to use another enzyme, Epicentre also has two MasterAmp™ PCR Optimization Kits that will help you to obtain the best possible PCR results with thermostable enzymes frequently used in PCR, such as Taq, Pfu, Tth, Tfl DNA polymerases. These MasterAmp PCR Optimization Kits contain a series of 12 MasterAmp PCR 2X PreMixes that have been meticulously tested and represent a complete range of PCR conditions frequently encountered. Each MasterAmp 2X PreMix contains all components needed for PCR except for the primers, the template, and the PCR enzyme.

First, use the MasterAmp™ PCR Optimization Kit (Cat. No. MO7201) to perform PCR with your template, primers, and each of the 12 MasterAmp PreMixes. Select the PreMix that gives optimal results. Then, use the same MasterAmp PCR PreMix to obtain reliable, consistent PCR usng the same DNA target/primer set.

STEP 1. Find the optimal MasterAmp PCR PreMix. Do PCR with your template, primers and PCR enzyme in the 12 PreMixes.

A. A 75%-GC-rich ApoE gene region was amplified in total human genomic DNA using PreMixes A-L. MasterAmp PCR PreMix K produced optimal results in Step 1.

STEP 2. Use the same MasterAmp PCR PreMix to obtain reliable, consistent PCR of the same sequence.

B. Subsequent PCR of the ApoE gene with the same primer pair and MasterAmp™ PreMix K gave consistent results. Subsequent PCR results are consistent and reliable using the optimal PreMix in Step 1.

MasterAmp PCR Optimization Kits; MasterAmp Taq DNA Polymerase; MasterAmp Tfl DNA Polymerase. Purchase of this product includes an immunity from suit under patents specified in the product insert to use only the amount purchased for the purchaser's own internal research. No other patent rights (such as 5´ Nuclease Process patent rights) are conveyed expressly, by implication, or by estoppel. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.



If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200

Protocols

Protocols for: MasterAmp™ PCR Optimisation Kits 

MasterAmp™ PCR Optimisation Kits (without Ammonuim Sulfate) Protocol

(catalogue number MOS001 / MO7201 / MO7205A→L) 

MasterAmp™ PCR Optimisation Kits (with Ammonuim Sulfate) Protocol

(catalogue number MOS02N / MO751N / MO755(A→L)N)

Please note: all protocols off site are the responsibility of the products supplier

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200

Notes

 

Epicentre® Forum Get your Epicentre® Forum - hot off the press!
Click here for direct link to Forum listings

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200

Applications & Benefits

Applications

  • Simplified PCR optimization with a thermostable DNA polymerase of choice.
  • PCR of difficult or high-GC templates.
  • PCR amplifications up to 20 kb.
  • Multiplex PCR.

Benefits

  • Fast, simple optimization.
  • Extremely high sensitivity and specificity using the PCR Enhancer Technology.
  • MasterAmp PCR PreMixes contain all components needed for successful PCR.
  • Generates PCR products suitable for both TA cloning and blunt-end cloning.

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200

Related products

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200