Cambio - Excellence in Molecular Biology

Oligo Synthesis

Oligo Synthesis : Supports, CPGs

Prices quoted are for single packs only. For multiples of the same product please request a quote. Some of Glen's products are hazardous and may be subject to additional shipping charges. Full product information is available on Glen Research's website.

dC-CPG 500

dC-CPG 500

Glen Research

Catalogue No.DescriptionPack SizePriceQty
20-2010-01dC-CPG 500 0.1g £14.00 Quantity Add to Order
20-2010-02dC-CPG 500 0.25g £18.00 Quantity Add to Order
20-2010-10dC-CPG 500 1.0g £68.00 Quantity Add to Order
20-2110-13dC-CPG 500 1x10µm £91.00 Quantity Add to Order
20-2110-41dC-CPG 500 4x1.0µm £55.00 Quantity Add to Order
20-2110-42dC-CPG 500 4x0.2µm £36.00 Quantity Add to Order
20-2210-14dC-CPG 500 1x15µm £136.00 Quantity Add to Order
20-2210-41dC-CPG 500 4x1.0µm £55.00 Quantity Add to Order
20-2210-42dC-CPG 500 4x0.2µm £36.00 Quantity Add to Order

Description

dC-CPG 500

Structure

Catalog Number: 20-2010-xx

(20-2110-xx, 20-2210-xx, 20-2510-xx)

Description: dC-CPG 500

5'-Dimethoxytrityl-N-benzoyl-2'-deoxyCytidine,
3'-succinoyl-long chain alkylamino-CPG 500
    F.W.: 289.18

Diluent: Not Applicable
Coupling: No changes needed from standard method recommended by synthesizer manufacturer.
Deprotection: Deprotect using the protocol required by the nucleobases.
Storage: Controlled room temperature or lower, dry
Stability in Solution: Not Applicable

STERLING SUPPORTS

All Glen Research CPG supports use the standard long chain alkylamino (lcaa) linker but differ in the glass pore size, 500Å, 1000Å or 2000Å. The 500Å support is appropriate for shorter sequences, while the 1000Å supports perform better in the synthesis of longer (>30-mer) DNA sequences. The 2000Å support is best for very long (>150-mer) oligonucleotides. We have instituted an additional QC test for supports to show the length of oligo that can be prepared before a drop-off in coupling due to steric effects begins to occur. The drop-off point is recorded in the Certificate of Analysis. All Glen Research supports are fully end-capped to ensure that the CPG surface is totally inert, thereby avoiding the introduction of impurity sequences containing deletions at the 3’-terminus.

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200