Cambio - Excellence in Molecular Biology

Transfection-EZ Biosystems

Transfection-EZ Biosystems: Cell Lines

Avalanche®- Cell Line-specific Transfection Reagent series:

Perform maximum transfection efficiency for more than 170 different primary cells and cell lines including 124 cancer cell lines (e.g. All of NCI60 cancer cell lines). Each of the cell type/cell line-specific transfection reagents in our Avalanche® series was individually formulated.

If you are looking for primary cell type-transfection reagents then click Click here

 


 

Learn why you should use Avalanche® Cell Type-Specific Transfection reagents

 

How EZ Biosystems developed Avalanche® Cell Type-Specific Transection Reagents

 



EKVX Cell Avalanche® Transfection Reagent (human lung carcinoma cell)

KVX Cell Avalanche® Transfection Reagent is a new class of unique chemical formulations specifically formulated and optimized for transfecting EKVX cells. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for EKVX cells

EZ Biosystems

Catalogue No.DescriptionPack SizePriceQty
EZT-EKVX-1-05EKVX CellTransfection Reagent (human lung carcinoma cell)0.5 ml £620.00 Quantity Add to Order
EZT-EKVX-1-15EKVX CellTransfection Reagent (human lung carcinoma cell)1.5 ml £1,051.00 Quantity Add to Order

Description

Cell Line Information:
Cell Line Name: EKVX
Tissue Origin: Lung Carcinoma; Adenocarcinoma; NS; NS
The cell line EKVX was established following passage of the original tumor cells through nude mice, providing a possible source of the X-MLV found in the EKVX cells.
EKVX is one of the cell lines of the NCI-60 panel which represents different cancer types and has been widely utilized for drug screening and molecular target identification.
Supplier: Developmental Therapeutics Program, National Cancer Institute,Frederick,MD 21701

The Transfection Reagent:
EKVX Cell Avalanche® Transfection Reagent is a new class of unique chemical formulations specifically formulated and optimized for transfecting EKVX cells. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for EKVX cells. For details of the developing process of this reagent, please go to: How did EZ Biosystems develop Avalanche® Cell type/cell line specific transfection reagent series?


Features:

  • Specifically optimized to deliver nucleic acids into EKVX cells
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • Deliver single or multiple plasmids
  • Synthesized from 100% animal origin-free components, making it easy to validate the absence of zoonotic diseases, such as BSE or viruses, in research experiments or cells lines
  • Easy-to-use protocol: Just mix nucleic acids with the reagent to form complexes and simply add the mixture to cells
  • Active in serum-containing medium
  • Suitable for Reverse Transfection  
  • Compatible with transfection in any plate format
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems
 
Data:
FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on EKVX cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for EKVX cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this EKVX Cell Avalanche® Transfection Reagent.
 

For Other Cells:
EKVX Cell Avalanche® Transfection Reagent (human lung carcinoma cell) can also be used on the following cells with high transfection efficiencies.

HOP-62 Cell
HOP-92 Cell  
NCI-H226 Cell  
NCI-H322M Cell
NCI-H460 Cell
NCI-H23 Cell
NCI-H1975 Cell
Calu-3 Cell
NCI-H358 Cell
293 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200